Hayward pool heater says lo

Hayward Insights provides expert advice, tips, and industry updates to help pool owners and enthusiasts with their swimming pool experience. Gain insight. ... Phase Heaters: 1.0000: Pool Type: In Ground: Product Dimensions: 24 " x 34 " x 29.5 "Product Height: 24 in: Product Length: 29.5 in: Product Weight: 195 lb: Product Width: 34 in:

Hayward pool heater says lo. Hayward H400FD Manuals. Manuals and User Guides for Hayward H400FD. We have 13 Hayward H400FD manuals available for free PDF download: Service & Installation Manual, Manuel D'entretien Et D'installation, Owner's Manual, Quick Manual, Quick Reference Manual.

Jun 14, 2016 · I have Hayward H150FDN Universal H-Series, Low NOx, 150,000 BTU, Natural Gas, Pool and Spa Heater and I am getting a LO code with is a flow problem. I have my intermatic timer set for 755am to turn on and give my equipment power, then at 8am the Hayward pump turn on.

Pump is running, water is flowing through heater, heater plugged in, gas on. Service panel says Lo and "service". ... I am getting LO on my Hayward gas pool heater. It was fine 2 weeks ago but the weather has been cold so we did not turn the heater on. I previously cleaned the cartridges when we opened the pool.Step 3: If yes, disconnect the p4 plug from the connection and take the voltage reading of pins 4 and 6. Here you will also get reading for 110-125 VAC. Step 4: In case you are getting the right voltage in both cases, it’s a must say that the fuse is blown and you need to replace it.Faulty water temperature switch, malfunctioning vent pressure switch, and defective temperature limit switch are accountable for displaying the Hayward pool heater LO code. Also, the damaged flow switch diaphragm and clogged filter are responsible for showing this code on your pool heater. However, going through the article, you will learn all about reasons behind LOThe Hayward heater LO code indicates a fault in the temperature limit switch, vent pressure switch, or water pressure switch. To fix it, ensure the pump is on, is wired and connected well, the water flow …Service panel says Lo and "service". ... I have Hayward pool heater #H250PED 2, new 7/6/06. When we opened pool in May, the electronic readout keys had no response but the little red pool light and last yrs temp setting of 81 deg were lite u ...

Jan 11, 2022 · Step 3: If yes, disconnect the p4 plug from the connection and take the voltage reading of pins 4 and 6. Here you will also get reading for 110-125 VAC. Step 4: In case you are getting the right voltage in both cases, it’s a must say that the fuse is blown and you need to replace it. Step 1. Turn off the power supply to the pool heater. Step 2. Wait for at least five minutes to allow the heater to cool down. Step 3. Turn the power back on and press the reset button. This button is typically located near the heater’s control panel or on the heater’s interior.Hawyard H400 Heater "LO" flashing. Thread starter TNorth225; Start date Apr 21, 2009; Jump to latest Follow Reply Forums. Equipment - Build, Use, and Repair ... I recently bought a house with a in ground pool/hot tub combo that includes a Hayward H400 pool heater. It was a bank owned house where the pool had been sitting without filtering for ...Hayward 100K BTU HeatPro Heat and Cool Pump. $ 4,299.00. Pay over time with Bread. Hayward 100K Heating & Cooling capability includes active defrost for low ambient operation. Unit will heat and cool water to maintain the desired temperature. Multi-speed fan modulates speed automatically for quiet, energy-efficient operation.Last fall we closed our pool too late and it froze and it leaked. So with much research we purchased the Hayward 250,000 btu propane heater. Electrician hooked it up on 220. It fired right up and heats a bit more tha 2 degrees per hour. Some say it is loud. But its quieter than the little 100,000 btu we had. We hope for years of use. Easy to ...I fixed Lo error! hayward spa heater was giving me a LO error when I turned it This is how I fixed it within less than a minute easy steps.

Jun 14, 2016 · I have Hayward H150FDN Universal H-Series, Low NOx, 150,000 BTU, Natural Gas, Pool and Spa Heater and I am getting a LO code with is a flow problem. I have my intermatic timer set for 755am to turn on and give my equipment power, then at 8am the Hayward pump turn on. The Hayward Pool Heater SF Code is a safety feature that prevents the pool heater from over-heating. The code stands for "Safety Fault" and is displayed when the temperature in the heater exceeds 110 degrees Fahrenheit (43°C). It will shut off power to the pool heater until it can cool down to a safe temperature.>Pool Supply Unlimited has parts for Hayward Universal H-Series Low NOx Induced Draft Pool & Spa Heater | 400,000 BTU | Propane | H400FDP. POOL. ... Hayward Heater Display Board H-Series Low NOx Models | IDXL2DB1930 ... ayudarle a diagnosticar los problemas de su equipo y escuchar acerca de cómo podemos mejorar y todo lo que está en su mente ...Pool guy here says Hayward conversion kit (natural gas to propane) not letting gas through. ... Hayward H300FDN. I replaced the pressure switch but still getting a LO signal and heater won't start ... I have a H series Hayward pool heater and it will not ignite. this is an electronic ignition.

Coborn's pharmacy huron sd.

Hayward's pool heater saves money by being the most energy efficient solution for any pool/spa. It's designed for ultimate performance, comfort and durability while being environmentally responsible. For rapid comfort, we offer the Universal solution. Universal H-Series. H300FDP Universal H-Series Propane Gas 300,000 BTU Low NOx (Expert Line ...For people using gas water heaters, two options are offered--natural gas or propane. According to Energy Star, 15 percent of a home’s energy use is attributed to heating water. Bot...Hayward is always looking for ways to make pool and spa ownership as simple and effortless as possible. The latest example of this is the new Universal H-Series pool and spa heater. Combining advanced technology with universal-fit flexibility, it's a smart choice for virtually any new installation or existing system upgrade delivering state of- the …Hayward's pool heater saves money by being the most energy efficient solution for any pool/spa. It's designed for ultimate performance, comfort and durability while being environmentally responsible. For rapid comfort, we offer the Universal solution. Universal H-Series. H300FDP Universal H-Series Propane Gas 300,000 BTU Low NOx (Expert Line ...

The gas shutoff outside the heater is closed. The gas valve inside the heater is turned off. Issues with the wiring of the Flame sensor and gas valve.Key Takeaways. The P5 code on Hayward pool heaters indicates a problem with the pressure switch. Common causes of the P5 code include clogged filters, improper water flow, and electrical issues. Troubleshooting steps for the P5 code involve checking water pressure, inspecting the heat exchanger, and verifying the gas supply.Jul 4, 2019 ... Hayward Pool Heater LO Code? Watch This!! Touched By The Sun Pools ... Pool Basics: How To Start/Light a Hayward H-Series Pool Heater. True ...The high limit switch on a Hayward pool heater is a safety device that is wired in series with the gas valve and the thermostat. If the water temperature going into the pool heater exceeds the maximum set, the gas valve will close, shutting off gas to the burners. ... Recommended Reading: How Much Does An Above Ground Pool Pump Cost. Hayward ...Last fall we closed our pool too late and it froze and it leaked. So with much research we purchased the Hayward 250,000 btu propane heater. Electrician hooked it up on 220. It fired right up and heats a bit more tha 2 degrees per hour. Some say it is loud. But its quieter than the little 100,000 btu we had. We hope for years of use. Easy to ... The Hayward Universal H-Series gas heater is one of the most energy-efficient Pool and Spa heating solutions on the market! Its ground-breaking hydraulic design reduces pump circulation run time, giving you an energy savings of up to 18%! This unit is perfect for the environmentally conscious Pool and Spa owner thanks to its Low NOx capabilities. LO Code Pages 40-43 IF Code Pages 44-46 AC Code Page 47 AO Code Page 48-50 ... Heater must then be in Spa or Pool Mode for operation. The heater will ... Hayward …Pool heaters work very straightforwardly: they generate heat to raise the water temperature. As long as they have a reliable water supply, the heater will not overheat. That’s why your unit will display the LO code when there’s something wrong with the water supply. The LO code signifies that there’s a low water pressure condition. […]The Hayward Universal H-Series gas heater is the "universal" energy efficient remedy for any new or existing pool or spa. An industry leading hydraulic design reduces circulation pump run time to provide energy savings of up to 18% when compared to less efficient competitors. PitschPlumbing. Generally, LO refers to the pressure switch, water pressure. This can be caused by either the diaphram in the flow switch has failed or the filters is clogged and/or pump is unable to make enough pressure to make the switch. Open the front panel of the heater and look up in to the right. You will see a round part with 2 wires ... Mar 23, 2023 · Turn off the electricity and gas going to the pool heater. Open the faceplate of the heater, then locate the pronged ignitor. Remove the retaining bracket and screws, then disconnect the ignitor from the motherboard’s wires. Contact the manufacturer for a like-for-like ignitor part number, then attach it to the motherboard’s wires. The hot tub reaches 103 manually but when it's turned on from the app it only heats up the pool so it goes to 85ish. Even when I switch the filter to the hot tub the heater thinks it's heating the pool so only reaches the max setting for the pool which is 90. … read more

A LO fault is constantly showing up. It was from great ... Is a Hayward pool heater ENMP6-21A capable of heating a 30,000 litre swimming pool that also has solar heating ... Pump is running, water is flowing through heater, heater plugged in, gas on. Service panel says Lo and "service".

FAQ: What are the Hayward pool heater lockout settings? The maximum lockout settings for the pool mode are 90ºF and 104ºF for the Spa mode by default.This unit is perfect for the environmentally conscious Pool and Spa owner thanks to its Low NOx capabilities. The Hayward Universal H-Series gas heater meets or exceeds the South Coast Air Quality Management District's (SCAQMD) Low NOx emission standards, making it ideal for use in states with strict air quality guidelines such as California.Stumbling upon a 'LO' code on your Hayward heater can be quite the head-scratcher. Don't worry, you're about to unravel the mystery behind this cryptic message. …HI My Hayward Hseries pool heater shows a LO and stops working when it rains. My temp dropped from 92 to 80. Contractor's Assistant: Who manufactured the pool? I can't recall. It is a semi-inground purchased through Great Escape 5 years ago. Heater is 5 years old. I replaced the heating tubes last summer. Universal H-Series Natural Gas 400,000 BTU Low NOx. Hayward. SKU: W3H400FDN. The Universal H-Series is an energy efficient, high performance, installation adaptable commitment to the pool service professional. Add to Compare. Add to Export. Cleaning the burners on your Hayward pool heater is essential for keeping it running smoothly. Follow these simple steps to get the job done: Step 1: Turn off the pool heater and disconnect the gas supply. Allow the unit to cool down before proceeding. Step 2: Remove the front panel of the heater to access the burners.Jun 20, 2022 · My pool heater quit working. It would try to start, but then fail. The error code "IF" was displayed. It was an "Ignition Failure Lockout". I looked at a...

Cox and collins funeral home mullins sc.

Pawn shop on fm 78.

The Hayward HeatPro 140K Electric Heat Pump is a high-efficiency heater, gives you the ideal water temperature while using 80% less energy than natural gas heaters. It offers an alternative way to heat your pool that is safe, reliable, and energy efficient. Hayward HeatPro Electric Heater takes the heat from the surrounding air and uses it to ... Follow the included steps to place the heater in bypass mode for external control. Step 1. Press the ‘MENU ICON’ button to place the heater in ‘STANDBY’ mode. Step. The ‘SPA’ indicator should illuminate & the display should show the Max Temp set point. Step 2. Press and hold the minus & plus buttons for 3 seconds. Key Takeaways. The P5 code on Hayward pool heaters indicates a problem with the pressure switch. Common causes of the P5 code include clogged filters, improper water flow, and electrical issues. Troubleshooting steps for the P5 code involve checking water pressure, inspecting the heat exchanger, and verifying the gas supply.This blower vacuum switch is designed to use with Hayward Universal H-Series Low NOx pool heater models H150FDN, H150FDP, H200FDN, H200FDP, H250FDN, H250FDP, H300FDN, H300FDP, H350FDN, H350FDP, H400FDN, H400FDP. Weighs 4.8 pounds.HU-429948972. 3 years ago. Hi I just hooked up a new 150,000 Hayward. With pump on low speed I get the LO code. So I put on high speed and LO code immediately goes away but then within 30 seconds I get HS code and shut down. 724-977-7371. Like.Reset the Heater: Sometimes, simply resetting the heater can clear the LO code. Turn off the heater, wait a few minutes, and then turn it back on. Professional Service: If you’ve tried the above steps and the LO code persists, it’s advisable to contact a professional pool heater technician. They can diagnose the issue more accurately and ...Posted April 16, 2010. The "LO" code means "Loop Open", referring to your safety loop switches. Most likely it's your pressure switch that's open due to low water flow usually caused by a dirty filter. The "60" code is really "bO" meaning "bypass operation" in which your heater's internal thermostat is bypassed so as to control the set ...Dec 21, 2023 · Key Takeaways. The P5 code on Hayward pool heaters indicates a problem with the pressure switch. Common causes of the P5 code include clogged filters, improper water flow, and electrical issues. Troubleshooting steps for the P5 code involve checking water pressure, inspecting the heat exchanger, and verifying the gas supply. May 25, 2022 · You need to put the heater in STANDBY Mode to get the bO code on the heater display. Press the mode button once to get the heater in STANDBY Mode. First, press and hold on to the Down key. Then, press and hold down the MODE key as well. You need to keep holding both keys for about three seconds. At this point, the “bO” message should appear ... We have a hayward pool heater - 21 foot pool. Pool just opened. Turned on heater - Says needs service - temp window says low. Propane is on. I go thru this every year. Contractor's Assistant: Who manufactured the pool? Don't know. Pool is about 5 years old. Tucker pools opens an closes it every year. They just opened it MondayHayward Gas Heater showing LO . ... The chemical part of opening is done. I put salt in today as pool temp was 72 degrees (heater hasnt been running yet) and i think I'm supposed to turn on the chlorinator but google says to wait 24 hours after putting in salt so I'm going to turn it on tomorrow. The variable pump has now been running for a ...Compatible Replacement for: Hayward H-Series ed2 Pool Heaters, Hayward H-Series LoNox models h150fdn, h150fdp, h200fdn, h200fdp, h250fdn, h250fdp, h300fdn, h300fdp, h350fdn, h350fdp, h400fdn, h400fdp ; Manufactured by Optimum Pool Technologies ; NOTE: This is a compatible aftermarket replacement part. The manufacturers' names and part numbers ... ….

Hayward's HeatPro Heat Pump, a high-efficiency heater, gives you the ideal water temperature while using less energy than natural gas heaters. It offers an alternative way to heat your pool that is safe, reliable, and energy efficient. To heat your pool water efficiently, the HeatPro takes the heat from the surrounding air and uses it to warm ...If you're looking for help fixing your Hayward Pool Heaters, look no further! Our comprehensive Hayward Pool Heaters Troubleshooting guide will explain commo...Reset the Heater: Sometimes, simply resetting the heater can clear the LO code. Turn off the heater, wait a few minutes, and then turn it back on. Professional Service: If you’ve tried the above steps and the LO code persists, it’s advisable to contact a professional pool heater technician. They can diagnose the issue more accurately and ...Jun 28, 2020 ... If you have an SF error code on your pool or spa Hayward heater I made a quick video how to fix it. I don't have an editing program so ...Pool heater question. This is a raypak pool heater manifold. Have a water sw open code. Where’s the switch. There two sets of wires running to probes. Ones a thermometer and the other is this little brass plug with two terminals coming off it. I’ve removed it and it’s not a switch. Thoughts ?The Universal H-Series Low NOx heater has an 84 percent industry-leading thermal efficiency and complies with all current California air quality emission standards. The low NOx emission makes it a perfect choice for the environmentally concerned pool owner. Enjoy a warmer pool this season without your fuel costs skyrocketing.Say more by seamlessly including video within your publication. ... HAYWARD ® POOL AND SPA/HOT TUB HEATERS H150FD, H200FD, H250FD, H300FD, H350FD & H400FD MODELS ... LO EE. USE ONLY HAYWARD ...Service LED ON: “LO” Code “LO” Code (Limit Open) may relate to water flow. Verify the pump is running & adequate water is flowing through heater. “LO” is NORMAL when the pump is turned off or there is insufficient water flow. Hayward pool heater says lo, Hayward H-Series heater for above ground pools and spas combines reliable technology with ease of operation and superior performance. H-Series heaters boast industry-leading hydraulic performance coupled with a 135,000 BTU rating for faster speed-to-heat capability. Their intuitive electronic panel is also quick and easy to operate, so pool ..., Use the “Mode” key to change your heater’s settings. Select the “Standby” Option and put the heater on it. Press the remote’s “Down” key and hold it and then press the Mode key and hold it simultaneously. For 3 seconds, hold down both the “Down” and “Mode” keys as long as the “bo” code doesn’t remove from your ..., The tech did the install and ran the heater only for a few minutes to check for ignition and stuff. He had done some other plumbing work so he didn't want to run in too long, or the pool pump either, so that the PVC glue really had some time to cure. The heater is a 400,000 BTU Hayward Universal HC Series Model HDF400 Pool Heater., When it comes to enjoying your pool year-round, a properly sized pool heater is crucial. Choosing the right size heater ensures that your pool stays at the desired temperature, reg..., Lo-Nox. Before purchasing a heater, a pool owner should become more acquainted with their state health and safety codes. Lo-Nox heaters are a more environmentally safe way to heat your pool. ... Barreling Ahead with Another says: February 12, 2021 at 10:34 AM. ... I am looking to replace our heater. We had a …, Hayward H-Series heater for above ground pools and spas combines reliable technology with ease of operation and superior performance. H-Series heaters boast industry-leading hydraulic performance coupled with a 135,000 BTU rating for faster speed-to-heat capability. Their intuitive electronic panel is also quick and easy to operate, so pool ..., LO on Hayward Hseries Pool heater. 2 years in October. H150 or 250. A week Backwash look for air leaks backwash. It - Answered by a verified Pool and Spa Expert. ... Pool just opened. Turned on heater - Says needs service - temp window says low. Propane is on., Jul 5, 2016 ... Wired a Hayward pool heater, propane, trips every few hours ... pool heater tripping ... He says nameplate is 12 amps so did you put a amp meter on ..., One of the most common calls we receive during season is the FLO error on a pool heater. Learn more about what causes this error and how we resolve it., Step 1 Step 2 Press the 'MENU ICON' button to place the heater in 'STANDBY' mode. Step 3 Press and hold the minus & plus buttons for. Hayward HDF400 | Universal HC Series Heater Troubleshooting Guide - Page 11. setting the max temp lock-out set point, the LEDs & display should flash rapidly., Some of the most reviewed products in HAYWARD Pool Heaters are the HAYWARD Universal H-Series Propane Gas 150,000 BTU Low NOx Pool Heater with 5 reviews, and the HAYWARD Universal H-Series Natural Gas 400,000 BTU Low NOx Pool Heater with 4 reviews. Related Searches. heyward propane pool heater., I have a Hayward H400FDN heater. Have a aqua links control in side my house . When I turn on my heater and select pool on my aqua links, it works perfect but when I switch to spa heat it stays on pool … read more, For hayward pool heater if code repair, check the pressure switch and ensure proper pressure is being reached. Hayward pool heaters display an “if” code when the pressure switch is not closed. This is caused by insufficient water flow, closed valves, air in the system, or a clogged filter. It is important to identify and fix the issue ..., Replacement Parts. Hayward Electric 5.5kW Spa Heater 240V. Replacement Parts. Hayward H-Series 100K BTU Heater Natural Gas. Replacement Parts. Hayward Universal ASME. H-Series 250K BTU Heater Propane. Replacement Parts. Hayward Universal ASME H-Series 400K BTU Heater Natural Gas., ProLogic: How It Works. • All ProLogic systems are salt chlorination ready and can control 4-16 high voltage relays, 3-4 valve actuators and 1-2 heaters. • These systems can manage: Hayward Variable Speed Pumps, ColorLogic Lighting, Sense & Dispense, AquaConnect Homenet, as well as a wide variety of remotes., HI My Hayward Hseries pool heater shows a LO and stops working when it rains. My temp dropped from 92 to 80. Contractor's Assistant: Who manufactured the pool? I can't recall. It is a semi-inground purchased through Great Escape 5 years ago. Heater is 5 years old. I replaced the heating tubes last summer., The hayward pool heater drain plug is located at the bottom of the heater unit. When removing the drain plug, ensure the heater is turned off, the gas supply is disconnected, and the water has cooled down to prevent any accidents. Introducing a well-rounded swimming pool maintenance involves several essential tasks, and one of them is draining ..., • Any pool or pool/spa combination • Single, shared or dual equipment • Up to 4 bodies of water Features and Benefits: • Eliminate complexity. With the most intuitive, icon-based user- interface, set your controller to fit your preferences quickly and easily • Modular Expandability. Equipped with 4 relays with flexibility to upgrade., Universal H-Series Propane Gas 300,000 BTU Low NOx (Expert Line) Item #H300FDP. EXPERT LINE products are only available through your local pool professional. The Universal H-Series is an energy efficient, high performance, installation adaptable commitment to the pool service professional. Standard cupro nickel heat exchanger., So the H250 with an input of 250,000 BTU’s actually puts 210,000 BTU’s into the water per hour. Discounting heat loss (which there is always some) if you are using a Hayward gas heaters to heat the 18,000 gallon pool we have discussed above you will need: 22.58 therms of natural gas. 24.75 gallons of propane., LO Code Pages 40-43 IF Code Pages 44-46 AC Code Page 47 AO Code Page 48-50 ... Heater must then be in Spa or Pool Mode for operation. The heater will ... Hayward Part # FDXLFSKF30 (Qty. 10) Step 1: Page 14 Verify incoming voltage to heater is present (110-125 or 220-245 VAC), if, The Hayward pool heater spa mode is designed to maintain a specific “spa-like” temperature in the pool. To use this mode, enable “Spa mode” from the control panel, set the required temperature, and let the pool heater warm the water. Once ready, test the water. This process is a joy to behold for those who want to soak themselves in ..., >Pool Supply Unlimited has parts for Hayward Universal H-Series Low NOx Induced Draft Pool & Spa Heater | 300,000 BTU | Natural Gas | H300FDN. ... Hayward Heater Display Board H-Series Low NOx Models | IDXL2DB1930. ... ayudarle a diagnosticar los problemas de su equipo y escuchar acerca de cómo podemos mejorar y todo lo que está en su mente ..., With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. It is being practiced by thousands of pool owners just like you. We are a registered 501(c)3 non-profit that is funded by user donations., Low and High Salt Alarms can be observed when the salt in parts per million is outside of the expected range in a Body Of Water. Salt Chlorination takes place while the Salt Level is between 2400 and 3800 ppm . A Low Salt Alarm is generated when the Salt ppm is between 2400 and 2700 ppm for Standard. For Low Salt Monitoring it is between 800 ..., The Hayward pool heater spa mode is designed to maintain a specific “spa-like” temperature in the pool. To use this mode, enable “Spa mode” from the control panel, set the required temperature, and let the pool heater warm the water. Once ready, test the water. This process is a joy to behold for those who want to soak themselves in ..., This unit is perfect for the environmentally conscious Pool and Spa owner thanks to its Low NOx capabilities. The Hayward Universal H-Series gas heater meets or exceeds the South Coast Air Quality Management District's (SCAQMD) Low NOx emission standards, making it ideal for use in states with strict air quality guidelines such as California. , Apr 22, 2023 · I fixed Lo error! hayward spa heater was giving me a LO error when I turned it This is how I fixed it within less than a minute easy steps. , The flow in a particular pool is affected by a number of factors, many of which you can't easily change like the size of your pipe, number of 90deg connections, etc. Heaters require 40gpm to operate., Locate the pilot light assembly on your pool heater. 2. Turn the gas control knob to the “Off” position and wait for 5 minutes. 3. Turn the knob to the “Pilot” position and press it down. 4. While holding down the knob, use a long lighter or match to ignite the pilot. 5., This unit is perfect for the environmentally conscious Pool and Spa owner thanks to its Low NOx capabilities. The Hayward Universal H-Series gas heater meets or exceeds the South Coast Air Quality Management District's (SCAQMD) Low NOx emission standards, making it ideal for use in states with strict air quality guidelines such as California., Models manufactured before Sept. 2010: measure across pins 1-2 (black & red), then 3-4 (white & blue) for 8-9 ohms. Models after Sept. 2010: measure for 4-5 ohms across the two terminal with wires. IF out-of-range, replace blower (pg. 20). IF correct, contact technical support (908)355-7995., Hawyard H400 Heater "LO" flashing. Thread starter TNorth225; Start date Apr 21, 2009; Jump to latest Follow Reply Forums. Equipment - Build, Use, and Repair ... I recently bought a house with a in ground pool/hot tub combo that includes a Hayward H400 pool heater. It was a bank owned house where the pool had been sitting without filtering …